(800) 432-8692 | (305) 681-8531

HX Series -Spiral Fluoropolymer (PTFE) Over The Side Heaters

From Process Technology

Thermal Protection (required) *

SKU: N/A Category:

Description

Product Features and Benefits:

SUPERIOR CHEMICAL RESISTANCE: Inert to most aqueous acid, alkaline, anodizing and pickling solutions up to 212°F (100°C).

RUGGED CONSTRUCTION: Heavy wall fluoropolymer (PTFE) covered stainless steel element reduces permeation and eliminates the need for gas purge systems. Guaranteed 100% pinhole free.

OUTSTANDING PERFORMANCE: Low watt density design (10 watts/square inch, 1.5w/cm2) for long service life.

CORROSION RESISTANT HEAD: Vapor tight, flame retardant polypropylene terminal enclosure with 3-foot (.9m) flexible PVC liquid tight conduit.

SAFETY FEATURES:

  • Grounded internal metal element.
  • Thermal protector built in. Replaceable P1 fuse standard for solutions up to 190°F (88°C).
  • Non-floating construction.

CERTIFICATIONS: UL (1-6 kW), CSA, and CE.

SIZES: 500 watts to 9,000 watts.

VOLTAGES: 120, 240 or 480 volts.Single phase only. (Contact Us For 208,380,415, 600 and other voltages available)

OPTIONS AVAILABLE (Contact Us):

  • Replaceable thermal protectors:
  • P4: for solutions from 190°F (88°C) to 220°F (104°C).

 

  • Resettable thermal protectors:
  • P2: bi-metal switch for solutions up to 190°F (88°C).
  • P8: type-J thermocouple for solutions from 190°F (88°C) to 210°F (99°C).
  • P3: type-J thermocouple for solutions from 210°F (99°C) to 250°F (121°C).

 

  • Longer vertical lengths (cold zones).
  • Polypropylene guards: recommended for applications up to 180°F (82°C).
  • Fluoropolymer (PTFE) guards: recommended for chromic acid or solutions over 180°F (82°C).
  • Special configurations.
  • Longer wire and conduit lengths.
  • Flexible continuous fluoropolymer leads (P3 protector only).
  • Lower watt densities for highly viscous solutions and technical acids.
  • Temperature and level controls sized to match the heater.
WATTS VOLTS OVERALL LENGTH
In./(mm)
HOT
ZONE
In./(mm)
Fluoropolymer (PTFE) – Teflon SHIP
WGT.
Lbs./(kg)
500 120
240
11
(280)
5
(125) HX.5111-**
HX.5211-**
6
(2.5)
1000 120
240
11
(280)
7
(180)
HX1111-**
HX1211-**
7
(3.5)
2000 120
240
480
17
(430)
12
(305)
HX2117-**
HX2217-**
HX2417-**
8
(4)
3000 240
480
23
(585)
16
(405)
HX3223-**
HX3423-**
13
(6)
4000 240
480
29
(735)
20
(510)
HX4229-**
HX4429-**
15
(7)
5000 240
480
35
(890)
25
(635)
HX5235-**
HX5435-**
18
(8)
6000 240
480
40
(1015)
29
(735)
HX6240-**
HX6440-**
21
(10)
8000 240
480
47
(1195)
37
(940)
2HX8247-**
2HX8447-**
25
(12)
9000 240
480
54
(1375)
44
(1120)
2HX9254-**
2HX9454-**
28
(13)

Single Phase Only.

Longer vertical lengths, and flexible risers available (Contact Us)

Standard Guard is polypropylene. Fluoropolymer guards recommended for chromic acid and solutions exceeding 180°F (82°C).  (Contact Us)

**THERMAL OVERLOAD PROTECTION SYSTEM: (Controller and Heater protection system must match)

Protector 1 (P1)-Standard over-temperature control system utilizes a heat sensitive fuse to detect overheat conditions. The fuse, placed inside a thermowell, positioned in contact with the heater sheath, will cut power to the heater in the event of low liquid level.

Protector 2 (P2) and Protector 3 (P3) -Optional systems provide the same reliable over temperature protection as the Protector 1; however, the control systems feature a heat sensing thermostat. Should the tank€™s liquid level drop to a preset overheat point, the thermostat will trip and an audible alarm will sound, cutting power to the heater. This eliminates dangerous operating conditions. After filling the tank, the immersion heater can be quickly made operational by pushing the reset button on the control to restore power. Protector III is designed for flexible lead or high temperature fluoropolymer (PTFE) heater applications only. DO NOT wire P3 or PT-3 devices directly to power or heater load as a dangerous short circuit will result with irreparable damage to the heater. Please refer to wiring diagrams for proper installation.

GUARDS:
Guards recommended for all fluoropolymer and quartz heaters. Standard guard is polypropylene. Special fluoropolymer (PTFE) guards for chromic acid solutions exceeding 180°F (82°C) available (contact us)

***All heaters must be operated in conjunction with appropriate temperature controls and thermal systems***

Click Here To Download:
HX SERIES DATA SHEET (including dimensional diagram)  .PDF
**Thermal Overload Protection  .PDF

Additional information

Weight N/A

Reviews

There are no reviews yet.

Be the first to review “HX Series -Spiral Fluoropolymer (PTFE) Over The Side Heaters”

Your email address will not be published. Required fields are marked *